Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Echocardiography ; 26(8): 934-42, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19968681

RESUMO

The effect of dobutamine on carotid and brachial arteries compliance and the association of L-arginine as a potential nitric oxide pathway restorer were evaluated in patients with heart failure. Twenty-seven outpatients participated. Drugs used for the treatment of heart failure were withheld at least 24 hours before the study. The carotid and brachial artery diameters and hemodynamic variables were evaluated by ultrasonography and Doppler in baseline conditions, with dobutamine, with flow-mediated dilatation (FMD), and with placebo or L-arginine alone and associated with dobutamine. There was a significant increase in carotid peak blood flow with dobutamine when compared with that at baseline (P = 0.0001) or with L-arginine or placebo (P = 0.0001 and P = 0.0001, respectively), with increase of the cardiac index (P = 0.0001). Dobutamine did not increase carotid arterial compliance. FMD significantly increased the brachial peak blood flow (P = 0.0022) and the artery diameter (P = 0.0001). Dobutamine did not change the brachial artery diameter. Brachial peak blood flow was increased with dobutamine alone or associated with placebo or L-arginine comparing with L-arginine or placebo alone (P = 0.0168 and P = 0.0140, respectively), but was not increased compared with that at baseline. L-arginine infusion was not associated with changes in carotid, brachial, or in the cardiac index. We concluded that dobutamine increased carotid peak blood flow in patients with heart failure, although without changing the arterial compliance. The FMD of brachial artery was maintained, while brachial artery response to dobutamine infusion was less reliable. The carotid artery may be under the direct influence of the heart, while the brachial artery may be under predominant local control.


Assuntos
Arginina/administração & dosagem , Artéria Braquial/efeitos dos fármacos , Artéria Braquial/fisiopatologia , Dobutamina/administração & dosagem , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Braquial/diagnóstico por imagem , Quimioterapia Combinada , Módulo de Elasticidade/efeitos dos fármacos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/administração & dosagem
2.
Rev. bras. ecocardiogr ; 18(1): 49-52, jan.-mar. 2005. tab
Artigo em Português | LILACS | ID: lil-404071

RESUMO

Objetivo: Avaliar a correlação entre insuficiência mitral (IM)e alterções na resposta eletrocardiográfica do teste egométrico, em portadores de prolapso valvar mitral. Método: Estudou-se 189 portadores de prolapso mitral através de ecocardiograma e teste de esforço. 57 por cento do sexo feminino, idade média de 39,1(+ 12 anos), com função ventricular normal, ausência de quaisquer outras valvopatias ou de miocardiopatias e sem histórico prévio de doença arterial coronária. A presença de infradesnível do segmento ST(morfologia horizontal e descendente) e arritmias supraventriculares, definiram um desfecho primário composto. Alterações morfológicas do segmento ST e arritmias (supraventriculares ou ventriculares) foram considerados desfechos secundários, quando avaliados de forma independente. Resultados: 36 pacientes (19 por cento) apresentaram o desfecho composto, sendo 21 com IM(P=0,06). 84 pacientes (44,4 por cento) apresentaram IM. 11 pacientes apresentaram alterações morfológicas do segmento ST, destes, 8 apresentaram IM(P=0,05). Dos 107 pacientes (56,6 por cento) com degenerção mixomatosa, 21 apresentaram o desfecho composto (P=0,81). 31 pacientes (16,4 por cento) apresentaram arritmias supraventriculares ou ventriculares isoladas e raras durante o teste ergométrico, sendo 18 com IM(P=0,95). Conclusão: A presença de insuficiência mitral, no portador de prolapso valvar mitral, foi predictiva de alterações morfológicas do eletrocardiograma no teste ergométrico.


Assuntos
Humanos , Masculino , Feminino , Adulto , Insuficiência da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/diagnóstico , Teste de Esforço/métodos
3.
Arq Bras Cardiol ; 83(3): 248-52; 243-7, 2004 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-15375474

RESUMO

OBJECTIVE: To compare clinical and laboratory data in patients with mitral stenosis undergoing open commissurotomy or balloon valvuloplasty, who were followed up for 5 years. METHODS: Eighty-one patients were prospectively assessed prior to the procedure (PRE) and immediately after the procedure, in the immediate postoperative period (IPO), and followed up yearly for 5 years (PO12M, PO24M, PO36M, PO48M, and PO60M). They were randomized into the following 2 groups: GC (group undergoing open commissurotomy): 37 patients (32.4 +/- 7.2 years; 89.2% females); and GV (group undergoing balloon valvuloplasty): 44 patients (32.9 +/- 9.5 years; 90.9% females). The patients' assessment comprised the following items: functional class, occurrence of events, electrocardiography, and Doppler echocardiography. RESULTS: A significant improvement in functional class occurred in most patients. Three patients in GC and in GV were in functional class III in PO60M. No difference in the mitral gradient was observed between the groups. A difference in the mean mitral valve areas was observed between the groups during the entire evaluation. No patients died. In regard to the IPO of GC, 3 patients had moderate mitral insufficiency (MI), and 3 had bleeding (1 was reoperated upon). In the IPO of GV, 4 patients had moderate MI, 1 had severe MI, 2 had cardiac tamponade, and 1 patient required surgery due to severe MI. Over 60 months, 9 GV patients evolved to moderate or severe MI, while 6 GC patients evolved to moderate or severe MI, and 2 other GC patients required surgery due to double mitral dysfunction. CONCLUSION: The rate of success in open mitral commissurotomy and balloon mitral valvuloplasty was 100%, and the rate of complications was low. During follow-up, a mild elevation in mitral gradient and a drop in mitral valve area were observed in both groups.


Assuntos
Oclusão com Balão , Cateterismo , Estenose da Valva Mitral/terapia , Adulto , Distribuição de Qui-Quadrado , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Estudos Prospectivos
4.
Arq. bras. cardiol ; 83(3): 243-252, set. 2004. ilus, tab, graf
Artigo em Inglês, Português | LILACS | ID: lil-382726

RESUMO

OBJETIVO: Comparar dados clínicos-laboratoriais em portadores de estenose mitral submetidos à comissurotomia ou valvoplastia por cateter-balão, obtidos ao longo de 5 anos de acompanhamento. MÉTODOS: Foram acompanhados, prospectivamente, 81 pacientes no pré (PRÉ), imediatamente após o procedimento (POI), e ao longo de cinco anos (PO12M, PO24M,..., PO60M) e randomizados em dois grupos: GC: 37 pacientes (32,4 ± 7,2 anos e 89,2 por cento mulheres) e GV: 44 pacientes (32,9 ± 9,5 anos e 90,9 por cento mulheres). A avaliação compreendeu: classe funcional, ocorrência de eventos, eletrocardiograma e ecodopplercardiograma. RESULTADOS: Houve melhora expressiva da classe funcional na maioria dos pacientes, três casos do GC e do GV estavam em classe funcional III no PO60M. Não houve diferença em relação ao gradiente mitral entre os grupos. Houve diferença das médias de área valvar mitral entre os grupos durante toda avaliação. Não ocorreram óbitos. No POI do GC observamos 3 casos com insuficiência mitral (IM) moderada, 3 com sangramento (1 reoperado) e, no GV, 4 casos com IM moderada, 1 com IM importante, 2 com tamponamento cardíaco, 1 caso necessitou cirurgia por IM importante. Ao longo de 60 meses, no GV, 9 casos evoluiram com IM moderada ou importante e no GC, 6 casos evoluiram com IM moderada ou importante e outros dois necessitaram cirurgia por dupla disfunção mitral. CONCLUSAO: Ambos os métodos obtiveram 100 por cento de sucesso com baixa taxa de complicações. No seguimento, houve elevação discreta do gradiente mitral e queda de área valvar mitral em ambos os grupos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estenose da Valva Mitral/terapia , Distribuição de Qui-Quadrado , Ecocardiografia Doppler , Seguimentos , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral , Estudos Prospectivos
6.
Radiol. bras ; 31(6): 349-54, dez. 1998. ilus, tab
Artigo em Português | LILACS | ID: lil-267841

RESUMO

Resumo: Este estudo visa fazer a correlaçäo entre a clínica, a ecocardiografia transtorácica (ETT) e a ecocardiografia transesofgica (ETE) no diagnóstico diferencial dos defeitos do septo interatrial (DSIA) e hipertensäo pulmonar (HP) em adultos. Realizamos ETT a ETE em 30 pacientes com diagnóstico de DSIA baseado em critérios de ausculta cardíaca, radiológicos e eletrocardiográficos. Três critérios, em 16 pacientes (grupo B). Foram determinados a sensibilidade, a especificidade, a acurácia e os valores preditivos positivo e negativo para a ETT, admitindo-se os resultados da ETE como ''gold standard''. A sensibilidade da ETT para o diagnóstico de DSIA é baixa 50 (por cento), a especificidade é de 75-90 (por cento), a acurária de 60-66 (por cento), o valor preditivo positivo de 75-83 (por cento), e o valor preditivo negativo de 37-75 (por cento), näo sendo capaz de diagnosticar os DSIAs tipo seio venoso. Catorze pacientes 46,6 (por cento) apresentaram diagnóstico final de HP, näo estando relacionada a DSIA


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Ecocardiografia , Ecocardiografia Transesofagiana , Comunicação Interatrial , Comunicação Interatrial/diagnóstico , Hipertensão Pulmonar/diagnóstico
7.
Radiol. bras ; 31(4): 201-11, jul.-ago. 1998. ilus
Artigo em Português | LILACS | ID: lil-225409

RESUMO

Esta revisäo analisa o potencial e as limitaçöes dos agentes utra-sonográficos na ecocardiografia, na ultra-sonografia abdominal e nas anormalidades vasculares periféricas. Uma nova perspectiva para melhorar a imagem colorida na área da ecocardiografia e na circulaçäo periférica abriu-se pela introduçäo dos agentes ultra-sonográficos transpulmonares. Os contrastes ultra-sonográficos, pela intensificaçäo da taxa de sinal ruído, aumentam o potencial da imagem colorida na visibilizaçäo do fluxo de baixa intensidade ou do fluxo de vasos profundos. O objetivo deste trabalho é elevar o nível de conhecimento relativo aos agentes ultra-sonográficos e, assim, promover seu uso apropriado


Assuntos
Humanos , Abdome , Doenças Vasculares Periféricas , Ecocardiografia , Ultrassom/classificação
8.
Arq. bras. cardiol ; 70(6): 415-421, Jun. 1998.
Artigo em Português | LILACS | ID: lil-320311

RESUMO

PURPOSE: To compare immediate and late (12 months) follow-up of clinical and Doppler echocardiographic results between percutaneous mitral balloon valvuloplasty and open commissurotomy in a prospective and randomized trial. METHODS: Eighty eight symptomatic patients with severe mitral stenosis and favorable anatomy were randomized in a prospective trial comparing the two procedures. All patients were submitted to clinical and Doppler echocardiographic evaluation before the procedures and immediate and twelve months thereafter. RESULTS: Mean mitral gradient (mmHg) decreased from 12.2 +/- 5.8 to 5.80 +/- 2.7 (p < 0.001) in commissurotomy group (CG) and from 11.7 +/- 6.1 to 5.0 +/- 2.4 (p < 0.001) in the balloon valvuloplasty group (VG). Mitral valve are (cm2) increased from 0.98 +/- 0.21 to 2.52 +/- 0.46 in CG and from 1.05 +/- 0.25 to 2.18 +/- 0.40 in VG (p < 0.001). In both groups there was a slight decrease in mitral valve area at 12 month follow-up. There was no death in either group. One patient in the VG had moderate mitral regurgitation and underwent surgery. At the 12 month follow-up, all patients in CG and 97.7of patients in VG were in New York Heart Association functional class I or II. CONCLUSION: Both procedures were safe and showed similar immediate improvement in mitral gradient and functional class. Mitral valve area had a greater increase immediately after commissurotomy, however, there was a significantly greater reduction in the CG after 12 months of follow-up, when compared to balloon valvuloplasty. In both groups, mitral gradient remained reduced and most patients did not change functional class during the follow-up.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos , Cateterismo , Estenose da Valva Mitral , Ecocardiografia Doppler , Estenose da Valva Mitral
9.
In. Sociedade de Cardiologia do Estado de Säo Paulo. SOCESP: cardiologia. Rio de Janeiro, Atheneu, 1996. p.168-72, ilus.
Monografia em Português | LILACS | ID: lil-263968
11.
Arq. bras. cardiol ; 64(1): 27-31, jan. 1995. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-156116

RESUMO

Objetivo - Avaliar a eficácia a longo prazo da valvoplastia mitral por cateter pela técnica do duplo baläo (VMC2B). Métodos - Sessenta e oito pacientes (76 por cento do sexo feminino), com média etária de 32 (15-69) anos, foram submetidos, consecutivamente, a VMC2B e realizaram avaliaçäo clínico-ecodopplercardiográfico no 12§ mês de acompanhamento (PO12M). Os critérios de seleçäo foram: sintomas de hipertensäo veno-capilar pulmonar, ausência de outra cardiopatia de indicaçäo cirúrgica, escore ecocardiográfico adequado, ausência de trombos intracavitários e insuficiência mitral (IM) no máximo discreta. Foram divididos em dois grupos: grupo A - composto por 7 (11 por cento) pacientes que apresentaram eventos cardíacos neste período e grupo B - composto por 61 pacientes que completaram o período de estudo sem eventos cardíacos. Näo havia diferença significativa entre os grupos em relaçäo aos dados demográficos, classe funcional (CF) e ao escore ecocardiográfico. Resultados - No grupo A, 3 pacientes apresentaram IM grave, em um caso houve insucesso e outro apresentou reestenose. Houve 2 óbitos näo relacionados ao procedimento. No grupo B, os resultados hemodinâmicos comparativos pré e imediatamente após (POI) VMC2B mostraram melhroa significativa, exceto em relaçäo ao índice cardíaco. Houve aumento do grau de IM em 17 (28 por cento) pacientes, tornando-se moderado em dois. A variaçäo da área valvar mitral (AVM) entre o PRÉ x POS x PO12M mostrou, comparando-se AVM no POI e PO12M, reduçäo significativa. Dois (3 por cento) pacientes com reduçäo >50 por cento do ganho inicial, 33 (54 por cento) entre 10 e 50 por cento e 26 (42 por cento) aquém de 10 por cento näo tiveram comprometimento da CF permanecendo em CF I/II. Conclusäo - A VMC2B é método atrativo para tratamento de estenose mitral em pacientes sintomáticos selecionados, com baixo índice de complicaçöes, melhora sintomática imediata que manteve-se a longo prazo apesar de reduçäo da AVM


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Cateterismo , Estenose da Valva Mitral/terapia , Seguimentos , Estenose da Valva Mitral/fisiopatologia , Hemodinâmica
12.
In. Sociedade de Cardiologia do Estado de Sao Paulo. Cardiologia: atualizaçäo e reciclagem. Rio de Janeiro, Atheneu, 1994. p.84-93.
Monografia em Português | LILACS | ID: lil-149017
13.
Arq. bras. cardiol ; 61(2): 87-91, ago. 1993. tab, graf
Artigo em Português | LILACS | ID: lil-148742

RESUMO

PURPOSE--To compare immediate and long term results balloon mitral valvuloplasty (BMV) using double balloon or bifoil balloon. METHODS--One hundred and thirteen consecutive cases of BMV used aleatory double balloon (group DB--55 cases) or bifoil balloon (group BF--16 cases). Patients were similar regarding to age, sex, valvopaty etiology, functional class and echocardiographic score. Seventy one (63 per cent ) patients achieved 12 months follow-up. RESULTS--In group DB there were 2 (4 per cent ) insuccess, 2 (4 per cent ) cardiac tamponade and 2 (4 per cent ) deaths, 91 per cent patients had immediate criteria of success. Mitral valve area (MVA) increased from 0.8 to 1.69cm2 and mitral gradient (G) by echodopplercardiographic (ECHO) decreased from 17.9 to 4.8mmHg. Three (5 per cent ) patients developed severe mitral regurgitation (MR) and needed surgical intervention. At follow-up 2 (4 per cent ) developed mitral restenosis. MVA estimated by ECHO study after one year follow-up was inferior to 1.15cm2 in 15 (32 per cent ) cases, between 1.5 and 2.0cm2 in 17 (37 per cent ) and superior to 2.0cm2 in 14 (31 per cent ). In group BF there were 2 (12.5 per cent ) insuccess, 4 (25 per cent ) developed severe MR occurring 1 death immediate post-operative mitral valve replacement. Among 14 (87 per cent ) success cases, MVA increased from 0.8 to 1.89cm2 and G decreased from 18 to 6.4mmHg. Lately 2 (12.5 per cent ) needed surgical intervention because significative MR. At 12th month follow-up the ECHO study showed that in one (10 per cent ) case MVA was < 1.5cm2, and in 3 (27 per cent ) cases was between 1.5 and 2.0cm2. CONCLUSION--There were similar good results in both groups, however group DB had more restenosis, cardiac tamponade and vascular complications and group BF had more severe MR


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Cateterismo , Estenose da Valva Mitral/terapia , Insuficiência da Valva Mitral/etiologia , Cateterismo/efeitos adversos , Ecocardiografia Doppler , Estenose da Valva Mitral , Protocolos Clínicos
14.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 3(3): 85-9, maio-jun. 1993.
Artigo em Português | LILACS | ID: lil-127722

RESUMO

Os autores objetivaram avaliar resultados imediatos e seguimento de um ano da valvoplastia mitral por cateter-balao (VMCB) utilizando o balao Inoue, em 40 pacientes portadores de estenose mitral (EM) sintomaticos e consecutivos, submetidos a VMCB; 37 mulheres, media etaria de 36 (22-67 anos), cinco portadores de ReEM. Trinta e sete estavam em classe funcional III/IV (NYHA) e a VMCBN foi realizada de urgencia em seis pacientes, devido a edema agudo dos pulmoes, incluindo duas gestantes. Foram analisados os dados hemodinamicos no pre e no pos-VMCB imediato e os dados ecodopplercardiograficos (ECO) no pre, pos imediato (POS) e apos 12 meses de seguimento (PO12M). Os resultados hemodinamicos pre X pos foram: gradiente mitral (G)17,6+/-7,6X6,3+/-5,5mmHg; area valvar mitral (AVM) 0,89+/-0,25X1,66+/-0,63cm2; pressao media do atrio esquerdo 25,5+/-9,0X14,3+/-6,4mmHg; pressao media de arteria pulmonar 34,8+/-13,0X23,8+/-10,8mmHg (todos p<0,0001) e indice cardiaco 2,8+/-0,5X2,9+/-0,8l/min/m2 (NS). Tres pacientes apresentaram insuficiencia mitral (IM) moderada, na ventriculografia esquerda pos-VMCB. As complicacoes relacionadas diretamente ao procedimento foram: 2 casos com tamponamento cardiaco necessitando drenagem cirurgica, 3 com comunicacao inter-atrial e 1 com perfuracao de aorta, sem tamponamento cardiaco. Um paciente apresentou acidente vascular cerebral, 72 horas apos a VMCB sem sequela motora. Houve 2 insucessos, sendo que 1 evoluiu para obito 2 meses apos VMCB. Os 29 pacientes que foram efetivamente acompanhados por um periodo de 12 meses nao apresentaram eventos cardiacos; os resultados do ECO PRE X POS X PO12M foram: AVM 1,00+/-0,24X2,12+/-0,33 e G 11,1+/-5,0+/-2,0X5,3+/-2,6. Todos os pacientes estavam em classe funcional I/II apos um ano de seguimento. Portanto, o balao Inoue mostra bons resultados imediatos e no seguimento por um periodo de 12 meses e serve como opcao terapeutica para EM em pacientes sintomaticos selecionados


Assuntos
Humanos , Gravidez , Feminino , Cateterismo , Insuficiência da Valva Mitral/cirurgia
15.
Arq. bras. cardiol ; 60(5): 301-305, maio 1993. ilus, tab
Artigo em Português | LILACS | ID: lil-126187

RESUMO

Objetivo - Analisar os reultados da valvoplastia mitral por cateter-baläo (VMCB) em pacientes de alto risco operatório. Métodos - Vinte (12// pacientes dentre 172 comsecutivos submetidos a VMCB foram considerados de alto risco operatório. Dezessete (85//) eram mulheres e a média etária de 43(18-69) anos. Treze (65//) encontravam-se em edema agudo dos pulmöes (3 gestantes, 2 com acidente vascular cerebral (AVC) prévio, 1 com tromboembolismo pulmonar e outro com insuficiência renal crônica) e 7 (35//) em classe funcional (CF) III (2 com insuficiência coronariana crônica, 2 com obesidade maligna, 1 com neoplasia de pulmäo, 1 com caquexia cardíaca e outro com AVC prévio). Realizaram VMCB pela técnica transeptal sendo utilizado duplo baläo em 10(45//), baläo Inoue em 5(25//), monofoíl em 3(15//) e bifoil em 2(10//) pacientes. Resultados - Dezessete (85//) pacientes com sucesso e 2 (10//) com melhora clínica expressiva. Os resultados hemodinâmicos pré x pós-VMCB foram: pressäo de átrio esquerdo (PAE) em mmHg 28,2 ñ 10,0 x 15,2 ñ 9,2 (n = 20) (p < 0,001); gradiente transvalvar mitral médio (G) em mmHg 21,2 ñ 10,7 x 10,7 ñ 6,7 (n = 18) ( , 0,001); área valvar mitral (AVM) em cm² 0,73 ñ 0,6 (n = 11) (p < 0,001); pressäo média de artéria pulmonar em mmHg 52,0 ñ 18,2 x 40,1 ñ 14,7 (n = 18) (p < 0,001); índice cardíaco em L/min/m² 2,1 ñ 0,4 x 2,5 ñ 0,6 (n = 14) (p < 0,001). No ecocardiograma os resultados comparativos pré, pós e após 6 meses da VMCB foram: área valvar mitral (cm²) 1,06 ñ 0,39 x 1,92 ñ 0,51 x 1,65 ñ 0,5 e gradientes transvalvar mitral (mmHg) 13,8 ñ 4,7 x 7,3 ñ 3,6 x 7,3 ñ 4,4. Houve 2 óbitos imediatos (tromboembolismo pulmonar e falência de multiplos órgäos) e 1 extra-hospitalar. As complicaçöes foram: 2(10//) pacientes com complicaçöes neurológicas, 1(5//) com comunicaçäo interatrial e outro com perfuraçäo da átrio direito (5//). Conclusäo - A VMCB oferece alternativa ao tratamento cirurgico em pacientes considerados de alto risco operatório e manutençäo do sucesso em seis meses de seguimento


Purpose - To evaluate percutaneous mitral balloon valvuloplasty (PMBV) in surgical high risk patients. Methods - Twenty (12%) patients out of 172 submitted to a PMBV were considered high surgical risk cases; 17 (85%) were women and mean age was 43 (18- 69). Thirteen (65%) were in acute pulmonary edema (3 were pregnant, 2 had previous cerebrovascular event, 1 had pulmonar thromboembolism and other had chronic renal failure), and 7 (35%) were in functional class (CF) III (2 had coronary artery disease, 2 severe obesity, 1 pulmonar neoplasy, 1 cardiac cachexia and one with previous cerebrovascular event). All patients underwent PMBV through transeptal technique. Double balloon was used in 10 (50%) patients; Inoue balloon in 5 (25%), monofoil in 3 (15%) and bifoil in 2 (10%). Results - Seventeen (85%) obtained success and 2 (10%) had clinical improvement. The hemodinamic results pre versus post-PMBV showed: left atrium pressure (LAP) mmHg 28.2±10,0 x 15.2±9.2 (n=20) (p<0.001), mitral mediam gradient (G) mmHg 21.2±10.7 x 10.7±.7 (n=18)(p<0.001), mitral valve area (MVA) cm2 0.73±0.3 x 1.73±0.6 (n=11) (p<0.001), pulmonary artery pressure mmHg 52.0±18.2 x 40.1±14.7 (n=18) (p<0.001) and cardiac index L/min/m2 2.1±0.4 x 2.5±0.6(n=14) (p<0.001). Comparative echocardiography results pre, post and 6 months after PMBV showed: MVA 1.06±0.39 x 1.92±0.51 x 1.65±0.5 and G 13.8±4.7 x 7.3±3.6 x 7.3±4.4. There were two immediate deaths (pulmonary thromboembolism and multiple organs failure) and other after hospital discharge. The complications were: 2 (10%) patients with neurological complications, 1 (5%) atrial septal deffect and other right atrium perforation (5%). Conclusion - PMBV offers an alternative to surgical treatment in high risk surgical patients and the results are maintained in the 6 month follow-up


Assuntos
Humanos , Masculino , Feminino , Gravidez , Recém-Nascido , Adolescente , Adulto , Pessoa de Meia-Idade , Cateterismo , Estenose da Valva Mitral/terapia , Ecocardiografia Doppler , Fatores de Risco , Seguimentos , Estenose da Valva Mitral/fisiopatologia , Estudo de Avaliação
16.
Rev. bras. cir. cardiovasc ; 7(4): 235-42, out.-dez. 1992. ilus, tab
Artigo em Português | LILACS | ID: lil-164372

RESUMO

A ecodopplercardiografia ocupa posiçao de destaque no diagnóstico das valvopatias, pois fornece dados sobre a anatomia valvar, a área estenótica, os gradientes pressóricos e o grau da regurgitaçao. Seu uso na cirurgia cardíaca, com a abordagem epicárdiaca, é bastante conhecido. O advento da abordagem transeofágica, por nao interferir no campo operatório, facilitou a sua utilizaçao. O objetivo deste trabalho foi estudar a utilidade da ETE na cirurgia da valva mitral. De julho de 1991 a janeirode l992, a ecodopplercardiografia transesofágica (ETE) monitorizou 198 cirurgias, das quais 65 foram sobre a valva mitral (VM). A idade variou de 8 a 62 anos e 42 pacientes eram do sexo feminino. A comissurotomia e papilarotomia (CP) foi o procedimento mais freqüente em 28 pacientes (pts), seguido do implante de bioprótese (BP) em 24 e da plastia (PL) em 19. A ETE pré-operatória confirmou o diagnóstico da lesao mitral em todos os pts, tendo acrescentado informaçoes quanto ao grau e direçao da insuficiência mitral (IM) em 8 dos 28 pts submetidos a CP. Modificou a orientaçao da abordagem da valva tricúspide em 9 oportunidades (3 por diagnosticar lesoes nao detectadas e 6 por evitar a abordagem desnecessária por melhor avaliaçao da lesao. Quanto aos pts submetidos a implante de BP, 6 já tinham próteses disfuncionantes, em 12 pts a BP foi implantada de imediato por decisao do cirurgiao e, em 6 pts, a BP foi implantada após a detecçao da presença de IM importante pós-correçao. Quanto ao pts submetidos a PL, 12 tinham prolapso, 6 tinham insuficiência coronária e 1 era pós-operatório tardio de correçao de defeito do septo atrioventricular. Em apenas l pt foi necessária nova CEC para nova plastia. A avaliaçao da IM pós CEC evidenciou 7 pts (lO por cento) com IM importante, sendo necessária nova CEC, e mostrou IM leve em 15 pts, moderada em 8 e importante em l onde nao foi realizada nova CEC. A ETE é um método de grande valor no auxílio do planejamento cirúrgico nas doenças da VM, bem como na avaliaçao imediata dos resultados operatórios possibilitando ao cirurgiao uma adequada análise anatômica e funcional da estrutura abordada.


Assuntos
Feminino , Humanos , Adolescente , Pessoa de Meia-Idade , Criança , Adulto , Ecocardiografia Doppler , Insuficiência da Valva Mitral/cirurgia , Próteses Valvulares Cardíacas , Cuidados Intraoperatórios , Insuficiência da Valva Mitral/diagnóstico
19.
Arq. bras. cardiol ; 55(2): 109-112, ago. 1990. tab
Artigo em Português | LILACS | ID: lil-89248

RESUMO

Objetivo: Estudar as características d e pacientes submetidos a valvoplastia mitral por cateter-balão (VMPB) que necessitaram de intervenção cirúrgica após a mesma. Casuística e Métodos: 105 pacientes submetidos a VMPB divididos em grupo I (Gl) composto por 18 pacientes operados e Grupo II (GII) por 87 não submetidos à intervenção cirúrgica no coração. Foram analisados: 1 ) idades; 2) sexo; 3) área valvar mitral (AVM) e gradiente transvalvar mitral médio (G) ao ecodopplercardiograma; 4) caráter da VMPB; 5) método utilizado na VMPB; 6) intervalo de tempo entre VMPB e cirurgia relacionado à indicação operatória; 7) achado operatório; 8) operação efetuada; 9) evolução pós-operatória...


Purpose: To study the characteristics of patients undergoing catheter-balloon mitral valvoplasty (CBVM) procedure who needed surgical intervention after CBMV. Patients and Methods: One hundred and five patients submitted a CBMV were divided in to Group I (GI) of eighteen surgical patients and Group II (GII) of eighty-seven non-surgical patients. The following parameters were analyzed. 1) age; 2) sex; 3) mitral valve area (MVA) and mean transvalvar gradiente (G) by echodopplercardography (2D); 4) Character of CBMV; 6) Relation of time between CBMV and Surgery with surgical indication; 7) Surgical fidings; 8) Surgical procedure and 9) Post-operative evolution...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Estenose da Valva Mitral/terapia , Recidiva , Estenose da Valva Mitral/cirurgia , /efeitos adversos
20.
Arq. bras. cardiol ; 50(4): 247-251, abr. 1988. ilus
Artigo em Português | LILACS | ID: lil-57609

RESUMO

De julho de 1985 a outubro de 1987 foram realizados 146 ecocardiogramas de coraçöes fetais. A idade materna variou de 15 a 46 anos (média de 26) e a idade gestacional variou de 12 a 41 semanas (média de 29). As gestantes foram divididas em três grupos: grupo I - com 88 gestantes sem patologias; grupo II - com 40 gestantes portadoras de doenças diversas (cardiopatias adquiridas, hipertensäo arterial sistêmica e diabete); grupo III - com 18 gestantes com cardiopatias congênitas. Em quatro casos (2,7%) de gestantes do grupo I, a ecocardiografia fetal foi realizada por indicaçäo do obstetra, devido a detecçäo de alteraçöes do ritmo cardíaco fetal. Em dois desses havia alteraçöes anatômicas do coraçäo: um com átrio único com defeito do septo atrioventricular forma parcial, confirmado no ecocardiograma pós-natal e outro com transposiçäo corrigida das grandes artérias com displasia tipo Ebstein da valva tricuspide, sendo confirmado apenas a segunda anomalia no exame pós-parto. Em um caso (0,7%) de gestanes do grupo III, detectou-se defeito do septo atrioventricular forma total confirmado pelo ecocardiograma pós-parto. O estudo ecocardiográfico fetal é um método confiável para o diagnóstico intra-útero de cardiopatias congênitas possibilitando uma adequada assistência ao recém-nato, além de permitir o acompanhamento evolutivo do crescimento das estruturas cardíacas através das medidas das dimensöes


Assuntos
Humanos , Feminino , Gravidez , Adolescente , Adulto , Pessoa de Meia-Idade , Ecocardiografia , Coração Fetal/fisiologia , Idade Gestacional , Complicações na Gravidez , Diagnóstico Pré-Natal , Frequência Cardíaca Fetal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...